High-Power AC Performance
to European Standards
The Voltris Type B AC Charger delivers robust, high-power AC charging performance engineered to the highest European electrical standards – purpose-built for 3-phase commercial infrastructure.
Charging Power
Maximum AC output – sufficient for overnight fleet charging and rapid top-up in commercial environments.
Output Voltage
3-phase, 400 V AC – fully compatible with European commercial grid infrastructure.
Max Current
32 A per phase – delivering full rated power within standard European circuit protection parameters.
Frequency
Native 50 Hz operation – no adaptation required for any EU market installation.
Connector Standard
Type 2 (IEC 62196) – the universal European EV charging connector standard, ensuring compatibility with all modern electric vehicles sold in the EU market.
Phase Configuration
3-phase AC operation maximizes charging speed for capable vehicles while maintaining backward compatibility with single-phase onboard chargers.
Communication & Connectivity
Future-Proof Connectivity for Every Site
The Voltris charger is built for seamless integration into modern charging networks. With support for leading open protocols and multiple physical connectivity options, it adapts to the infrastructure realities of every deployment site – whether wired or wireless.
OCPP 1.6 / 2.0.1 Ready
Compatible with all leading charge point management systems. Future-proof OCPP 2.0.1 readiness ensures long-term platform interoperability as the market evolves.
ISO 15118 – Plug & Charge
Automatic vehicle authentication without any user interaction. The vehicle and charger communicate directly, enabling seamless, one-step charging initiation.
Ethernet (LAN)
Wired network connectivity for stable, high-reliability installations where fixed infrastructure is available – ideal for fleet depots and managed commercial sites.
LTE / 4G Cellular
Cellular connectivity for locations without fixed network infrastructure. Enables deployment at any site regardless of existing telecoms provision.
OTA Firmware Updates
Remote over-the-air firmware updates ensure the system is always current with the latest features and security patches – no on-site engineer visits required.
Control & Intelligence
The Intelligence Layer That Drives Real Value
At the heart of the Voltris system is a sophisticated intelligence layer that continuously optimizes charging operations across single and multi-site deployments. Rather than reacting to conditions, the Voltris platform anticipates and pre-adapts – delivering measurable cost and efficiency gains for every operator.
Dynamic Pricing Engine
Automatically adjusts charging prices in real time in response to live energy market signals – day-ahead and intraday markets – ensuring operators always capture the most favorable tariff conditions.
Real-Time Load Balancing
Intelligently distributes available power across all active charging sessions simultaneously, preventing overloads and maximizing utilization of the available grid connection.
Site-Level Energy Optimization
Manages total site energy consumption holistically – coordinating chargers with other on-site loads to minimize peak demand charges and reduce overall energy costs.
Multi-Location Coordination
Synchronizes operations across multiple charging sites from a single unified platform – enabling portfolio-level optimization for operators managing large networks.
Predictive Control
Based on historical usage patterns and incoming data signals, the system anticipates demand and pre-optimizes charging schedules before peak periods begin.
Mechanical & Environmental
Built to Last in Any European Climate
The Voltris charger is engineered to withstand the most demanding physical and environmental conditions found across European deployment sites – from coastal saltwater environments to extreme continental temperature ranges. Premium materials and ratings reflect the quality expected in commercial infrastructure investments.
Enclosure Options
Available in stainless steel, aluminum, or fiberglass enclosures – each selected to meet the specific environmental demands of the deployment site.
Corrosion Resistance
Rated and tested for coastal and harsh environments – suitable for seaside installations, industrial zones and high-humidity locations.
Operating Temperature
−35°C to +55°C – full operational performance across the complete range of European climate conditions, from Scandinavian winters to Mediterranean summers.
IK10 Impact Rating
The highest available impact protection rating – resistant to vandalism and accidental physical damage in high-traffic public environments.
IP54 / IP65 Ingress Protection
Dust-tight and protected against water ingress – suitable for exposed outdoor installations without additional weatherproofing enclosures.
Installation Flexibility
Designed for both outdoor and indoor installation – adaptable to car parks, street-side deployments, covered facilities and depot environments.
Safety & Compliance
Certified Safe. Regulation-Ready.
The Voltris Type B AC Charger meets the full spectrum of European safety and regulatory requirements – not as an afterthought, but as a foundational design principle. Every unit ships with integrated hardware protection systems as standard, eliminating the need for additional external safety components.
Certifications & Standards
CE Compliant
Meets all applicable EU product safety directives for unrestricted market placement across all EU member states.
AFIR Compliant
Satisfies all requirements of the Alternative Fuels Infrastructure Regulation for public and semi-public charging infrastructure.
IEC 61851 & IEC 62196
Compliant with international standards governing EV conductive charging and connector specifications.
ISO 15118
Supports the international standard for vehicle-to-grid communication and Plug & Charge authentication.
Integrated Hardware Protection
Every Voltris charger incorporates comprehensive hardware-level protection systems as standard – eliminating single points of failure and reducing installation complexity:
RCD
Residual Current Device – protects users from electric shock in all fault conditions.
Overcurrent
Integrated overcurrent protection prevents cable and component damage under overload conditions.
Additional Protection
Supplementary integrated protection systems tailored to installation environment and regulatory requirements.